To create environmental sustainability all factories of Ananta understand its responsibility towards the society, human resource and environment. Hence, we ensure conservation of resources as per the prescribed local and international laws and regulations. We work towards.
We have highly trained and professionally competent Environmental responsible team who have been discharging their effective governance in the area of Environmental & Chemical related requirements even upcoming environmental challenges. The entire environmental compliance functions are being closely monitored & proper feedback given by Director-Compliance.
SL NO |
Name of Month |
Electricity from Generator (KWh) |
Purchased Electricity, REB (KWh) |
Total Energy Consumption in KWh |
Remarks |
1 |
January |
16992 |
227900 |
244892 |
|
2 |
February |
10206 |
265000 |
275206 |
|
3 |
March |
34260 |
268710 |
302970 |
|
4 |
April |
42444 |
278250 |
320694 |
|
5 |
May |
31650 |
288850 |
320500 |
|
6 |
June |
17838 |
190800 |
208638 |
|
7 |
July |
21282 |
248040 |
269322 |
|
8 |
August |
19014 |
201400 |
220414 |
|
9 |
September |
13518 |
157410 |
170928 |
|
10 |
October |
30240 |
217300 |
247540 |
|
11 |
November |
4494 |
221010 |
225504 |
|
12 |
December |
6402 |
274540 |
280942 |
|
Grand Total (KWh) |
3087550 |
|
|||
Per Month (KWh) |
257295.83 |
|
|||
Per Day (KWh) |
10223.68 |
|
SL NO |
Name of Month |
Ground Water Withdraw (m3) |
Rain Water Collection (m3) |
Total Water Consumption(m3) |
Remarks |
1 |
January |
14234 |
- |
14234 |
|
2 |
February |
13095 |
- |
13095 |
|
3 |
March |
13409 |
- |
13409 |
|
4 |
April |
15438 |
20 |
15458 |
|
5 |
May |
17414 |
20 |
17434 |
|
6 |
June |
11878 |
133 |
12011 |
|
7 |
July |
15113 |
68 |
15181 |
|
8 |
August |
12189 |
15 |
12204 |
|
9 |
September |
8398 |
52 |
8450 |
|
10 |
October |
12786 |
79 |
12865 |
|
11 |
November |
12175 |
- |
12175 |
|
12 |
December |
14798 |
- |
14798 |
|
Ground Total (m3) |
161314 |
||||
Per Month (m3) |
13442.83 |
||||
Per Day (m3) |
534.15 |
Ambient Air Quality:
SL NO |
Parameter |
Units |
Result |
DoE` 2005 Standard for Ambient Air |
IFC/World Bank Standard 2007 |
Remarks |
|||
West |
South |
East |
North |
||||||
1 |
SO2 |
µg/m3 |
112 |
99 |
95 |
100 |
365 |
125 |
Acceptable |
2 |
NOX |
µg/m3 |
57 |
66 |
65 |
61 |
100 |
200 |
Acceptable |
3 |
CO |
ppm |
1.7 |
1.9 |
2 |
1.9 |
10 |
NYS |
Acceptable |
4 |
PM10 |
µg/m3 |
112 |
111 |
113 |
119 |
150 |
150 |
Acceptable |
5 |
PM2.5 |
µg/m3 |
53 |
53 |
56 |
52 |
65 |
75 |
Acceptable |
6 |
SPM |
µg/m3 |
165 |
164 |
169 |
171 |
200 |
NYS |
Acceptable |
SL NO |
Parameter |
Units |
Result Boiler 1 |
Result Boiler 2 |
DoE (ECR amendment 2005) standards |
IFC/ World Bank standard 2007 |
EPA Standard |
Remarks |
1 |
O2 |
% |
20.35 |
19.30 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
0.58 |
0.94 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
5400 |
5750 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
68 |
72 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
73 |
72 |
NYS |
1460 |
100 |
Acceptable |
6 |
NO2 |
µg/m3 |
146 |
137 |
NYS |
150 |
NYS |
Acceptable |
7 |
SOX |
µg/m3 |
105 |
102 |
365 |
860 |
365 |
Acceptable |
8 |
PM10 |
µg/m3 |
75 |
62 |
150 |
50 |
150 |
Acceptable |
9 |
PM2.5 |
µg/m3 |
58 |
58 |
65 |
25 |
35 |
DoE Acceptable |
10 |
SPM |
µg/m3 |
133 |
120 |
200 |
NYS |
NYS |
Acceptable |
SL NO |
Parameter |
Units |
Results from Generator 1 |
Results from Generator 2 |
Results from Generator 3 |
DoE (ECR 1997 standard) |
IFC/ World Bank standard 2007 |
EPA standard |
Remarks |
1 |
O2 |
% |
19.80 |
20.50 |
18.90 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
1.06 |
1.08 |
1.05 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
8070 |
8055 |
6030 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
85 |
80 |
65 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
98 |
90 |
80 |
NYS |
1460 |
100 |
Acceptable |
6 |
NO2 |
µg/m3 |
143 |
140 |
145 |
NYS |
150 |
NYS |
Acceptable |
7 |
SOX |
µg/m3 |
128 |
120 |
98 |
365 |
860 |
365 |
Acceptable |
8 |
PM10 |
µg/m3 |
92 |
88 |
75 |
150 |
50 |
150 |
Acceptable |
9 |
PM2.5 |
µg/m3 |
65 |
65 |
60 |
65 |
25 |
35 |
Acceptable |
10 |
SPM |
µg/m3 |
157 |
153 |
135 |
200 |
NYS |
NYS |
Acceptable |
SL NO |
Waste Type |
Source of Waste |
Unit |
Annually |
Waste Classification |
Onsite Treatment |
Responsible Person |
Waste Disposal Route |
Remarks |
1 |
Reject Carton |
Production Floor |
Kg |
76254 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
2 |
Elastic Jhute |
Production Floor |
Kg |
18306 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
3 |
Poly |
Production Floor |
Kg |
9060.7 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
4 |
Chat |
Development Sector Production Floor |
Kg |
8593 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
5 |
Jhute |
Production Floor |
Kg |
502200 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
6 |
Rubbish |
Production Floor Development Sector |
Kg |
3720 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
7 |
Reject Garments |
Production Floor |
Kg |
57983 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
8 |
Fabric Cut Piece |
Production Floor |
Kg |
48018 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
9 |
Thread |
Production Floor |
Kg |
21003 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
10 |
Hanger (Plastic Item) |
Production Floor |
Kg |
1551 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
11 |
Thai Tukra |
Production Floor |
Kg |
73 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
12 |
Scrap |
Production Floor |
Kg |
8328 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
13 |
Sewing Jhute |
Production Floor |
Kg |
5323 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
14 |
Wastage Mobil |
Boiler & Generator Room |
Kg |
704 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
15 |
Draw cord |
Production Floor |
Pcs |
17.5 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
16 |
Wastage Tin |
Production Floor Development Sector |
Pcs |
2129 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
17 |
Empty Drum |
Chemical Store |
Pcs |
6 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
18 |
Drawstring |
Production Floor |
Kg |
522 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
19 |
Twill Tape |
Production Floor |
Kg |
557.5 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
20 |
Blanket |
Production Floor |
Kg |
13817 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
21 |
Medical Wastage |
Medical Room |
Kg |
920 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Handover to medical authority |
|
22 |
Fused Tube Light |
Office Room, Production floor, store, Boiler & generator Room etc. |
Pcs |
1100 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
Emission Point | Pollutant Name | Legal Emission Point | Obtained Result | Remarks | ||
---|---|---|---|---|---|---|
EPA Standard (USA) mg/m3 | DoE (ECR 1997) Standards mg/m3 | IFC/World Bank standard 2007 mg/m3 | ||||
Boiler 1 | O2 % | 30% | NYS | 15% | 2.98% | Acceptable |
CO2 % | NYS | NYS | NYS | 5.27% | ||
CO | 1 | 10 | NYS | 49.41 | ||
NO | NYS | 150 | 320 | 33.13 | ||
NOX | 100 | 150 | 320 | 52.79 | ||
SOX | 365 | 120 | NYS | 0 | ||
Boiler 2 | O2 % | 30% | NYS | 15% | 2.95% | Acceptable |
CO2 % | NYS | NYS | NYS | 1.79% | ||
CO | 1 | 10 | NYS | 65.22 | ||
NO | NYS | 150 | 1460 | 13.49 | ||
NOX | 100 | 150 | 1460 | 22.62 | ||
SOX | 365 | 120 | 860 | 0 | ||
Generator 1 | O2 % | 30% | NYS | 15% | 12.87% | Acceptable |
CO2 % | NYS | NYS | NYS | 6.02% | ||
CO | 1 | 10 | NYS | 387.30 | ||
NO | NYS | 150 | 1460 | 511.75 | ||
NOX | 100 | 150 | 1460 | 525.84 | ||
SOX | 365 | 120 | 860 | 0 | ||
Generator 2 | O2 % | 30% | NYS | 15% | 13.03% | Acceptable |
CO2 % | NYS | NYS | NYS | 5.89% | ||
CO | 1 | 10 | NYS | 526.37 | ||
NO | NYS | 150 | 1460 | 505.62 | ||
NOX | 100 | 150 | 1460 | 816 | ||
SOX | 365 | 120 | 860 | 0 |
SL NO | Waste Type | Source of Waste | Unit | Annually | Waste Classification | Onsite Treatment | Waste Disposal Route | Remarks |
---|---|---|---|---|---|---|---|---|
1 | Reject Carton | Production Floor | Kg | 96597 | Non-Hazardous | No | Handover to Contractor for recycling | |
2 | Wastage Elastic | Production Floor | Kg | 18276 | Non-Hazardous | No | Handover to Contractor for recycling | |
3 | Poly | Production Floor | Kg | 8056 | Non-Hazardous | No | Handover to Contractor for recycling | |
4 | Chat (Cement Bag) | Construction | Kg | 7643 | Hazardous | No | Handover to Contractor for reuse | |
5 | Jhute | Production Floor | Kg | 550474 | Non-Hazardous | No | Handover to Contractor for recycling | |
6 | Rabbish | Production Floor | Kg | 5000 | Non-Hazardous | No | Handover to Contractor for recycling | |
7 | Reject Garments | Production Floor | Kg | 48784 | Non-Hazardous | No | Handover to Contractor for recycling | |
8 | Fabric Cut Piece | Production Floor | Kg | 57873 | Non-Hazardous | No | Handover to Contractor for recycling | |
9 | Thread | Production Floor | Kg | 17701 | Non-Hazardous | No | Handover to Contractor for recycling | |
10 | Hanger (Plastic Item) | Production Floor | Kg | 3215 | Non-Hazardous | No | Handover to Contractor for recycling | |
11 | Sticker (Paper) | Production Floor | Kg | 5389 | Non-Hazardous | No | Handover to Contractor for recycling | |
12 | Scrap | Workshop | Kg | 5520 | Non-Hazardous | No | Handover to Contractor for recycling | |
13 | Plastic Bucket | Development Construction | Kg | 30 | Hazardous | No | Handover to Contractor for recycling | |
14 | Wastage Mobil | Boiler & Generator Room | Kg | 208 | Hazardous | No | Handover to Contractor for reuse | |
15 | Wastage Battery | Utility | Pcs | 19 | Hazardous | No | Returned to supplier | |
16 | Wastage Sewing Motor | Production Floor | Pcs | 15 | Hazardous | No | Returned to supplier | |
17 | Wastage Fan Motor | Office Room | Pcs | 01 | Hazardous | No | Returned to supplier | |
18 | Wastage Wood | Office, Production Floor, Utility etc. | Kg | 5950 | Non-Hazardous | No | Handover to Contractor for recycling | |
19 | Drawstring | Production Floor | Kg | 427 | Non-Hazardous | No | Handover to Contractor for recycling | |
20 | Twill Tape | Production Floor | Kg | 82 | Non-Hazardous | No | Handover to Contractor for recycling | |
21 | Blanket | Production Floor | Kg | 7328 | Non-Hazardous | No | Handover to Contractor for recycling | |
22 | Medical Wastage | Medical Room | Kg | 800 | Hazardous | No | Handover to medical authority | |
23 | Fused Tube Light | Office Room, Production floor, store, Boiler & generator Room etc. | Pcs | 1868 | Hazardous | No | Returned to supplier |
SL NO |
Name of Month |
Electricity from Generator (KWh) |
Purchased Electricity, REB (KWh) |
Total Energy Consumption in KWh |
Remarks |
|
1 |
January |
888.9 |
225000 |
225888.9 |
|
|
2 |
February |
389.43 |
232800 |
233189.43 |
|
|
3 |
March |
1282.08 |
242400 |
243682.08 |
|
|
4 |
April |
2751.29 |
255600 |
258351.29 |
|
|
5 |
May |
6414.99 |
216600 |
223014.99 |
|
|
6 |
June |
914.8 |
226800 |
227714.8 |
|
|
7 |
July |
5345.9 |
271800 |
277145.9 |
|
|
8 |
August |
891.6 |
246600 |
247491.6 |
|
|
9 |
September |
2778.5 |
226200 |
228978.5 |
|
|
10 |
October |
6479.4 |
273000 |
279479.4 |
|
|
11 |
November |
2085.8 |
265800 |
267885.8 |
|
|
12 |
December |
2975 |
225000 |
227975 |
|
|
Grand Total (KWh) |
2940797.69 |
|
||||
Per Month (KWh) |
245066.47 |
|
||||
Per Day (KWh) |
9737.74 |
|
SL NO |
Name of Month |
Ground Water Withdraw (m3) |
Total Water Consumption (m3) |
Remarks |
1 |
January |
5470 |
5470 |
|
2 |
February |
4365 |
4365 |
|
3 |
March |
6355 |
6355 |
|
4 |
April |
7650 |
7650 |
|
5 |
May |
4967 |
4967 |
|
6 |
June |
5606 |
5606 |
|
7 |
July |
4544 |
4544 |
|
8 |
August |
4921 |
4921 |
|
9 |
September |
3557 |
3557 |
|
10 |
October |
5610 |
5610 |
|
11 |
November |
5883 |
5883 |
|
12 |
December |
6085 |
6085 |
|
Ground Total (m3) |
65013 |
|
||
Per Month (m3) |
5417.75 |
|
||
Per Day (m3) |
215.27 |
|
Indoor Air quality:
SL NO |
Parameter |
Units |
Result |
DoE` 2005 Standard for Ambient Air |
IFC/World Bank Standard 2007 |
Remarks |
|
Sewing Section |
Cutting Section |
||||||
1 |
SO2 |
µg/m3 |
3.5 |
3.7 |
365 |
125 |
Acceptable |
2 |
NOX |
µg/m3 |
13 |
16 |
100 |
200 |
Acceptable |
3 |
CO |
ppm |
<1 |
<1 |
10 |
NYS |
Acceptable |
4 |
SPM |
µg/m3 |
37.5 |
43 |
200 |
NYS |
Acceptable |
SL NO |
Parameter |
Units |
Result Boiler 1 |
DoE (ECR amendment 2005) standards |
IFC/World Bank Standard 2007 |
EPA Standard |
Remarks |
1 |
O2 |
% |
2.98 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
5.23 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
152 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
120.5 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
137.7 |
NYS |
1460 |
100 |
Acceptable |
6 |
SO2 |
µg/m3 |
25.5 |
365 |
860 |
365 |
Acceptable |
7 |
SPM |
µg/m3 |
19.3 |
200 |
NYS |
NYS |
Acceptable |
SL NO |
Parameter |
Units |
Results from Generator 1 |
Results from Generator 2 |
DoE (ECR 1997 standard) |
IFC/ World Bank standard 2007 |
EPA standard |
Remarks |
1 |
O2 |
% |
14.63 |
14.52 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
278.7 |
242.5 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
7.56 |
5.34 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
432.3 |
356.9 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
723.2 |
452.5 |
NYS |
1460 |
100 |
Acceptable |
6 |
SOX |
µg/m3 |
15.6 |
14.6 |
365 |
860 |
365 |
Acceptable |
7 |
SPM |
µg/m3 |
37.9 |
31.3 |
200 |
NYS |
NYS |
Acceptable |
Waste Inventory-2017
SL NO |
Waste Type |
Source of Waste |
Unit |
Annually |
Waste Classification |
Onsite Treatment |
Responsible Person |
Waste Disposal Route |
Remarks |
1 |
Reject Carton |
Production Floor |
Kg |
947 |
Non-Hazardous |
No |
Mr. Md. Monowar Hosseain, DM. Admin
|
Sold to Contractor |
|
2 |
Metal |
Production Floor |
Kg |
76 |
Non-Hazardous |
No |
Mr. Md. Monowar Hosseain, DM. Admin |
Sold to Contractor |
|
3 |
Poly |
Production Floor |
Kg |
328 |
Non-Hazardous |
No |
Mr. Md. Monowar Hosseain, DM. Admin |
Sold to Contractor |
|
4 |
Wastage Jhute |
Production Floor |
Kg |
39618 |
Non-Hazardous |
No |
Mr. Md. Monowar Hosseain, DM. Admin |
Sold to Contractor |
|
5 |
Wastage Wood |
Production Floor |
Kg |
328 |
Non-Hazardous |
No |
Mr. Md. Monowar Hosseain, DM. Admin |
Sold to Contractor |
|
6 |
Wastage Mobil |
Boiler & Generator Room |
Kg |
258 |
Hazardous |
No |
Mr. Md. Monowar Hosseain, DM. Admin |
Sold to Contractor |
|
7 |
Fused Tube Light |
Office Room, Production floor, store, Boiler & generator Room etc. |
Kg |
76 |
Hazardous |
No |
Mr. Md. Monowar Hosseain, DM. Admin |
Sold to Contractor |
|
Emission Point | Pollutant Name | Legal Emission Point | Obtained Result | Remarks | ||
---|---|---|---|---|---|---|
EPA Standard (USA) mg/m3 | DoE (ECR 1997) Standards mg/m3 | IFC/World Bank standard 2007 mg/m3 | ||||
Boiler 1 | O2 % | 30% | NYS | 15% | 20.80% | Acceptable |
CO2 % | NYS | NYS | NYS | 2.64 | ||
CO | 1 | 10 | NYS | 1.20 | ||
NO | NYS | 150 | 320 | 2.15 | ||
NOX | 100 | 150 | 320 | 59 | ||
SOX | 365 | 120 | NYS | 64 | ||
Generator 1 | O2 % | 30% | NYS | 15% | 20.05 | Acceptable |
CO2 % | NYS | NYS | NYS | 1.59 | ||
CO | 1 | 10 | NYS | 1.96 | ||
NO | NYS | 150 | 1460 | 2.64 | ||
NOX | 100 | 150 | 1460 | 68 | ||
SOX | 365 | 120 | 860 | 68 | ||
Generator 2 | O2 % | 30% | NYS | 15% | 9.8 | Acceptable |
CO2 % | NYS | NYS | NYS | 1.35 | ||
CO | 1 | 10 | NYS | 1.99 | ||
NO | NYS | 150 | 1460 | 2.23 | ||
NOX | 100 | 150 | 1460 | 79 | ||
SOX | 365 | 120 | 860 | 64 |
SL NO | Waste Type | Source of Waste | Unit | Annually | Waste Classification | Onsite Treatment | Waste Disposal Route | Remarks |
---|---|---|---|---|---|---|---|---|
1 | Reject Carton | Production Floor | Kg | 4468 | Non-Hazardous | No | Handover to Contractor for recycling | |
2 | Wastage Mobil/Oil | Boiler & Generator Room | Kg | 246 | Hazardous | No | Handover to Contractor for reuse | |
3 | Poly | Production Floor | Kg | 912 | Non-Hazardous | No | Handoverto Contractor for recycling | |
4 | Wastage Wood | Office, Production Floor, Utility etc. | Kg | 476 | Non-Hazardous | No | Handover to Contractor for recycling | |
5 | Jhute | Production Floor | Kg | 46420 | Non-Hazardous | No | Handover to Contractor for recycling | |
6 | Fused Tube Light | Office Room, Production floor, store, Boiler & generator Room | Kg | 52 | Hazardous | No | Returned to supplier | |
7 | Medical Wastage | Medical Room | Kg | 628 | Hazardous | No | Handover to medical authority | |
8 | Metal | Production Floor | Kg | 249 | Non-Hazardous | No | Handover to Contractor for recycling |
Energy Consumption Summary-2017
SL NO |
Name of Month |
Electricity from Generator (KWh) |
Electricity from Solar Power Plant (KWh) |
Purchased Electricity, REB (KWh) |
Total Energy Consumption in KWh |
Remarks |
1 |
January |
8132.9 |
292.64 |
98315 |
106740.54 |
|
2 |
February |
11770.2 |
749.3 |
65985 |
78504.5 |
|
3 |
March |
20435.9 |
458.5 |
113950 |
134844.4 |
|
4 |
April |
36958.6 |
294.4 |
98315 |
135568 |
|
5 |
May |
45514.1 |
267.4 |
85595 |
131376.5 |
|
6 |
June |
30519 |
135 |
80030 |
110684 |
|
7 |
July |
13147.5 |
179 |
89835 |
103161.5 |
|
8 |
August |
24931.8 |
323.9 |
87185 |
112440.7 |
|
9 |
September |
23441.1 |
191.3 |
58035 |
81667.4 |
|
10 |
October |
35449.4 |
337.7 |
105470 |
141257.1 |
|
11 |
November |
8118.4 |
281.5 |
71815 |
80214.9 |
|
12 |
December |
4620.4 |
207.1 |
145750 |
150577.5 |
|
Grand Total (KWh) |
1367037.04 |
|
||||
Per Month (KWh) |
113919.75 |
|
||||
Per Day (KWh) |
4526.61 |
|
SL NO |
Name of Month |
Ground Water Withdraw (m3) |
Rain Water Collection (m3) |
Total Water Consumption (m3) |
Remarks |
1 |
January |
4183 |
--- |
4183 |
|
2 |
February |
3857 |
--- |
3857 |
|
3 |
March |
4107 |
--- |
4107 |
|
4 |
April |
4939 |
--- |
4939 |
|
5 |
May |
4583 |
--- |
4583 |
|
6 |
June |
3055 |
5 |
3060 |
|
7 |
July |
4386 |
55 |
4441 |
|
8 |
August |
4246 |
155 |
4401 |
|
9 |
September |
3388 |
55 |
3443 |
|
10 |
October |
3893 |
95 |
3988 |
|
11 |
November |
5003 |
--- |
5003 |
|
12 |
December |
5663 |
--- |
5663 |
|
Ground Total (m3) |
51668 |
|
|||
Per Month (m3) |
4305.67 |
|
|||
Per Day (m3) |
171.09 |
|
Ambient Air quality:
SL NO |
Parameter |
Units |
Result |
DoE` 2005 Standard for Ambient Air |
IFC/World Bank Standard 2007 |
Remarks |
|||
West |
South |
East |
North |
||||||
1 |
SO2 |
µg/m3 |
89 |
107 |
89 |
83 |
365 |
125 |
Acceptable |
2 |
NOX |
µg/m3 |
57 |
70 |
65 |
50 |
100 |
200 |
Acceptable |
3 |
CO |
ppm |
2 |
3 |
2.7 |
3.5 |
10 |
NYS |
Acceptable |
4 |
PM10 |
µg/m3 |
71 |
68 |
67 |
65 |
150 |
150 |
Acceptable |
5 |
PM2.5 |
µg/m3 |
60 |
59 |
53 |
47 |
65 |
75 |
Acceptable |
6 |
SPM |
µg/m3 |
131 |
127 |
120 |
112 |
200 |
NYS |
Acceptable |
Air Emission from Boiler:
SL NO |
Parameter |
Units |
Result Boiler 1 |
Result Boiler 2 |
DoE (ECR amendment 2005) standards |
IFC/ World Bank standard 2007 |
EPA Standard |
Remarks |
1 |
O2 |
% |
16.84 |
17.83 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
2.36 |
2.5 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
7893 |
5432 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
65.7 |
76.4 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
47.0 |
49.8 |
NYS |
1460 |
100 |
Acceptable |
6 |
NO2 |
µg/m3 |
69.4 |
54.7 |
NYS |
150 |
NYS |
- |
7 |
SOX |
µg/m3 |
288 |
265 |
365 |
860 |
365 |
Acceptable |
8 |
PM10 |
µg/m3 |
64 |
75 |
150 |
50 |
150 |
Acceptable |
9 |
PM2.5 |
µg/m3 |
43 |
43 |
65 |
25 |
35 |
Acceptable |
10 |
SPM |
µg/m3 |
107 |
118 |
200 |
NYS |
NYS |
Acceptable |
Air Emission from Generator:
SL NO |
Parameter |
Units |
Results from Generator 1 |
Results from Generator 2 |
DoE (ECR 1997 standard) |
IFC/ World Bank standard 2007 |
EPA standard |
Remarks |
1 |
O2 |
% |
20.80 |
20.56 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
1.4 |
1.6 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
4895 |
6867 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
43.7 |
55.9 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
54.7 |
65.3 |
NYS |
1460 |
100 |
Acceptable |
6 |
NO2 |
µg/m3 |
65 |
77.5 |
NYS |
150 |
NYS |
Acceptable |
7 |
SOX |
µg/m3 |
257 |
276 |
365 |
860 |
365 |
Acceptable |
8 |
PM10 |
µg/m3 |
82 |
81 |
150 |
50 |
150 |
Acceptable |
9 |
PM2.5 |
µg/m3 |
49 |
34 |
65 |
25 |
35 |
Acceptable |
10 |
SPM |
µg/m3 |
131 |
115 |
200 |
NYS |
NYS |
Acceptable |
Waste Inventory-2017
SL NO |
Waste Type |
Source of Waste |
Unit |
Annually |
Waste Classification |
Onsite Treatment |
Responsible Person |
Waste Disposal Route |
Remarks |
1 |
Reject Carton |
Production Floor |
Kg |
16031 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
2 |
Elastic Jhute |
Production Floor |
Kg |
417 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
3 |
Poly |
Production Floor |
Kg |
1452 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
4 |
Jhute |
Production Floor |
Kg |
147950 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
5 |
Reject Garments |
Production Floor |
Kg |
20605 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
6 |
Fabric Cut Piece |
Production Floor |
Kg |
491 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
7 |
Thread |
Production Floor |
Kg |
9261 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
8 |
Hanger (Plastic Item) |
Production Floor |
Kg |
1492 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
9 |
Plastic |
Production Floor |
Kg |
555 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
10 |
Moni Yards |
Production Floor |
Kg |
5387 |
Non-Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
11 |
Wastage Mobil |
Boiler & Generator Room |
Kg |
162 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
12 |
Medical Wastage |
Medical Room |
Kg |
240 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Handover to medical authority |
|
13 |
Fused Tube Light |
Office Room, Production floor, store, Boiler & generator Room etc. |
Pcs |
375 |
Hazardous |
No |
Md.Atier Rahman Executive-Environment |
Sold to Contractor |
|
SL NO | Waste Type | Source of Waste | Unit | Annually | Waste Classification | Onsite Treatment | Waste Disposal Route | Remarks |
---|---|---|---|---|---|---|---|---|
1 | Reject Carton | Production Floor | Kg | 20549 | Non-Hazardous | No | Handover to Contractor for recycling | |
2 | Wastage Mobil/Oil | Boiler & Generator Room | Kg | 156 | Hazardous | No | Handover to Contractor for reuse | |
3 | Poly | Production Floor | Kg | 980 | Non-Hazardous | No | Handover to Contractor for recycling | |
4 | Wastage Wood | Office, Production Floor, Utility etc. | Kg | 603 | Non-Hazardous | No | Handover to Contractor for recycling | |
5 | Jhute | Production Floor | Kg | 147500 | Non-Hazardous | No | Handover to Contractor for recycling | |
6 | Thread | Production Floor | Kg | 7044 | Non-Hazardous | No | Handover to Contractor for recycling | |
7 | Medical Wastage | Medical Room | Kg | 13.75 | Hazardous | No | Handover to medical authority | |
8 | Fabric Cut Piece | Production Floor | Kg | 8019 | Non-Hazardous | No | Handover to Contractor for recycling |
Environmental Sustainability Report-2017
Paradise Washing Plant Limited
Energy Consumption Summary-2017
SL NO |
Name of Month |
Electricity from Generator (KWh) |
Purchased Electricity, REB (KWh) |
Total Energy Consumption in KWh |
Remarks |
1 |
January |
0.0 |
191400 |
191400 |
|
2 |
February |
0.0 |
180600 |
180600 |
|
3 |
March |
2488 |
197400 |
199888 |
|
4 |
April |
4777.94 |
271800 |
276577.94 |
|
5 |
May |
10579.4 |
235200 |
245779.4 |
|
6 |
June |
9409.3 |
167400 |
176809.3 |
|
7 |
July |
8698.5 |
273600 |
282298.5 |
|
8 |
August |
5036.9 |
249000 |
254036.9 |
|
9 |
September |
5437.9 |
237879 |
243316.9 |
|
10 |
October |
10802.9 |
247000 |
257802.9 |
|
11 |
November |
2689.6 |
217017 |
219706.6 |
|
12 |
December |
5809.5 |
196904 |
202713.5 |
|
Grand Total (KWh) |
2730929.94 |
|
|||
Per Month (KWh) |
227577.49 |
|
|||
Per Day (KWh) |
9042.81 |
|
Total Water Consumption Summary-2017
SL NO |
Name of Month |
Ground Water Withdraw (m3) |
Rain Water Collection (m3) |
Total Water Consumption (m3) |
Remarks |
1 |
January |
52806 |
--- |
52806 |
|
2 |
February |
48276 |
--- |
48276 |
|
3 |
March |
52984 |
--- |
52984 |
|
4 |
April |
57464 |
--- |
57464 |
|
5 |
May |
56710 |
--- |
56710 |
|
6 |
June |
44387 |
--- |
44387 |
|
7 |
July |
58279 |
--- |
58279 |
|
8 |
August |
56031 |
--- |
56031 |
|
9 |
September |
41914 |
470 |
42384 |
|
10 |
October |
58593 |
--- |
58593 |
|
11 |
November |
57292 |
--- |
57292 |
|
12 |
December |
56745 |
--- |
56745 |
|
Ground Total (m3) |
641951 |
|
|||
Per Month (m3) |
53495.92 |
|
|||
Per Day (m3) |
2125.67 |
|
Air Emission Summary-2017
Ambient Air quality:
SL NO |
Parameter |
Units |
Result |
DoE` 2005 Standard for Ambient Air |
IFC/World Bank Standard 2007 |
Remarks |
1 |
SOX |
µg/m3 |
3.5 |
365 |
125 |
Acceptable |
2 |
NOX |
µg/m3 |
13.0 |
100 |
200 |
Acceptable |
3 |
CO |
ppm |
<1 |
10 |
NYS |
Acceptable |
4 |
SPM |
µg/m3 |
39.0 |
200 |
NYS |
Acceptable |
Air Emission from Boiler:
SL NO |
Parameter |
Units |
Result Boiler 1 |
Result Boiler 2 |
DoE (ECR amendment 2005) standards |
IFC/ World bank standard 2007 |
EPA standard |
Remarks |
1 |
O2 |
% |
2.98 |
2.95 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
7.23 |
7.56 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
256.7 |
157 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
120.5 |
123.3 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
137.7 |
134.4 |
NYS |
1460 |
100 |
Acceptable |
6 |
SOX |
µg/m3 |
25.5 |
23.4 |
365 |
860 |
365 |
Acceptable |
7 |
SPM |
µg/m3 |
21.2 |
21.7 |
200 |
NYS |
NYS |
Acceptable |
Air Emission from Generator:
SL NO |
Parameter |
Units |
Results from Generator 1 |
Results from Generator 2 |
DoE (ECR 1997 standard) |
IFC/ World Bank standard 2007 |
EPA standard |
Remarks |
1 |
O2 |
% |
14.89 |
14.92 |
NYS |
15% |
30% |
Acceptable |
2 |
CO2 |
% |
8.25 |
7.89 |
NYS |
NYS |
NYS |
- |
3 |
CO |
µg/m3 |
290.6 |
311.21 |
10000 |
NYS |
1000 |
Acceptable |
4 |
NO |
µg/m3 |
489.9 |
499.8 |
100 |
1460 |
100 |
Acceptable |
5 |
NOX |
µg/m3 |
590.8 |
578.9 |
NYS |
1460 |
100 |
Acceptable |
6 |
SO2 |
µg/m3 |
18.5 |
19.2 |
365 |
860 |
365 |
Acceptable |
7 |
SPM |
µg/m3 |
38.5 |
35.5 |
200 |
NYS |
NYS |
Acceptable |
Waste Inventory-2017
SL NO |
Waste Type |
Source of Waste |
Unit |
Annually |
Waste Classification |
Onsite Treatment |
Responsible Person |
Waste Disposal Route |
Remarks |
1 |
Reject Carton |
Production Floor |
Kg |
421 |
Non-Hazardous |
No |
Md. Iqbal Hossain Manager- Administration |
Sold to Contractor |
|
2 |
Empty Chemical Drum |
Production Floor |
Kg |
2588 |
Hazardous |
No |
Md. Iqbal Hossain Manager- Administration |
Sold to Contractor |
|
3 |
Poly/ Plastic |
Production Floor |
Kg |
1598 |
Non-Hazardous |
No |
Md. Iqbal Hossain Manager- Administration |
Sold to Contractor |
|
4 |
Metal |
Production Floor |
Kg |
1706 |
Hazardous |
No |
Md. Iqbal Hossain Manager- Administration |
Sold to Contractor |
|
5 |
Used Battery |
Production Floor |
Kg |
112 |
Hazardous |
No |
Md. Iqbal Hossain Manager- Administration |
Sold to Contractor |
|
6 |
Fused Tube Light |
Office Room, Production floor, store, Boiler & generator Room etc. |
Kg |
103 |
Hazardous |
No |
Md. Iqbal Hossain Manager- Administration |
Sold to Contractor |
|
Waste Type | Source of Waste | Unit | Annually | Waste Classification | On Site Treatment | Waste Disposal Route | Remarks |
---|---|---|---|---|---|---|---|
Rejected Cartoon | Production Floor | kg | 385 | Non-Hazardous | No | Handover to Contractor for Recycling | |
Metal | Production Floor | kg | 2593 | Non-Hazardous | No | Handover to Contractor for Recycling | |
Poly/Plastic | Production floor | kg | 2764 | Hazardous | No | Handover to Contractor for Recycling | |
Used tube light | Production floor & Office | kg | 116 | Hazardous | No | Handover to Contractor for Recycling | |
Empty Drum | Production floor | kg | 3224 | Hazardous | No | Handover to Contractor for Recycling |
Test Parameters | Result | Bangladesh Standard | Test Method |
---|---|---|---|
PH | 7.3 | 6-9 | APHA 4500-H+ B:2012 & U.S EPA 150.2 |
Total Suspended Solids (TSS) | 27 | <100 ppm | APHA 2540 D:2012 |
Chemical Oxygen Demand (COD) | 128 | <200 ppm | APHA 5220 B:2012 & U.S EPA 410.3 |
Biological Oxygen Demand (BOD5) | 24 | <50 ppm | APHA 5220 B:2012 |
2014 © Ananta Companies Bangladesh. ALL Rights Reserved.